Тhree-phase outdoor unit AJY072LALDH for Fujitsu Airstage VRF system, V-IV Series

Тhree-phase outdoor unit AJY072LALDH for Fujitsu Airstage VRF system, V-IV Series

  • Cooling Capacity: 22.4 kW
  • Heating Capacity: 22.4 kW
  • Maximum connectable indoor units: 17*1
  • Maximum pipe lenght: 700 m
  • Maximum height difference (upper/lower): 50/40 m
  • Operating Range:
    • Cooling: -15 to 46°C
    • Heating: -20 to 21°C

 
Technical Specifications of three-phase outdoor unit AJY072LALDH for Fujitsu Airstage VRF system, V-IV Series
Rated capacity range HP 8
Model name AJY072LALDH
Unit 1
Unit 2
Unit 3
AJY072LALDH
Maximum connectable indoor units*1 17
Connectable capacity range of indoor units kW 11.2 - 33.6
Power source 3-phase, 4-wire, 400V~, 50Hz
Capacity Cooling kW 22.4
Nominal Heating 22.4
Max. Heating 25.0
Input power Cooling kW 5.95
Nominal Heating 5.42
Max. Heating 6.26
EER Cooling W/W 3.76
COP Nominal Heating 4.13
Max. Heating 3.99
SEER Cooling 7.09
SCOP Heating 3.83
ηc Cooling % 281.0
ηh Heating 150.0
Air flow rate High m3/h 11,100
Sound pressure level*2/
Power level
Cooling % 58 / 79
Heating 59 / 80
Max. External static pressure Pa 82
Compressor motor output kW 7.5
Heat exchanger fin Blue fin
Net Dimensions Height mm 1,690
Width 930
Depth 765
Weight kg 252
Refrigerant Type (Global Warming Potential) R410A (2,088)
Charge kg (CO2eq-T) 11.7 (24.4)
Connection pipe diameter Liquid mm 12.70
Gas 22.22
Operating Range Cooling °CDB -15 to 46
Heating -20 to 21

Note: Specifications are subject to the following conditions:
Cooling: Indoor temperature of 27°CDB/19°CWB, and outdoor temperature of 35°CDB/24°CWB.
Heating: Indoor temperature of 20°CDB/(15°CWB), and outdoor temperature of 7°CDB/6°CWB.
Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m.
When cooling operation is be conducted at an outdoor air temperature below -5°C, the outdoor unit must be installed in a position that is higher than or equal to that of the indoor units.
*These specifications are determined by ducted combination.
*Multiple outdoor units are not certified by Eurovent.

  1. Minimum connectable indoor unit number is 2.
    However, the ARXC72 and ARXC90 can be used with a signal connection.
  2. The noise level is the value measured in an anechoic room.

When measured in an actual installation, the measured value is typically larger than the indicated value due to ambient noise and reflections.
* These specifications are determined by ducted combination.

Manufacturer Fujitsu Airstage
Series V-IV
Outdoor Unit AJY072LALDH
Power supply (V/ø/Hz) 400 / 3 / 50
Cooling Capacity (kW) 22.4
Heating Capacity (kW) 22.4
EER (Energy Efficiency in Cooling) 3.76
COP (Energy Efficiency in Heating) 4.13
SEER (Seasonal Cooling Efficiency) 7.09
SCOP (Seasonal Heating Efficiency) 3.83
Sound Pressure Outdoor Unit - Cooling/Heating dB(A) 58 / 59
Sound Power Outdoor Unit - Cooling/Heating dB(A) 79 / 80
Dimensions - Outdoor Unit WxHxD (mm) 930 x 1,690 x 765
Weight - Outdoor Unit (kg) 252
Maximum Pipe Lenght (m) 700
Maximum Height Difference (m) 50 / 40
Operation Range - Cooling (°C) -15 ~ 46
Operation Range - Heating (°C) -20 ~ 21
Refrigerant (type) R410A
Warranty 3 years