- New
- Cooling Capacity: 45.0 kW
- Heating Capacity: 42.0 kW
- Maximum connectable indoor units: 34*1
- Maximum pipe lenght: 700 m
- Maximum height difference (upper/lower): 50/40 m
- Operating Range:
- Cooling: -10 to 46°C
- Heating: -20 to 21°C
| Technical Specifications of three-phase outdoor unit AJY144GALDH for Fujitsu Airstage VRF system, VR-IV Series | |||
|---|---|---|---|
| Rated capacity range | HP | 16 | |
| Model name | AJY144GALDH | ||
| Unit 1 Unit 2 Unit 3 |
AJY144GALDH | ||
| Maximum connectable indoor units*1 | 34 | ||
| Connectable capacity range of indoor units | kW | 11.3 - 67.5 | |
| Power source | 3-phase, 4-wire, 400V~, 50Hz | ||
| Capacity | Cooling | kW | 45.0 |
| Nominal Heating | 42.0 | ||
| Max. Heating | 48.0 | ||
| Input power | Cooling | kW | 15.71 |
| Nominal Heating | 11.81 | ||
| Max. Heating | 14.98 | ||
| EER | Cooling | W/W | 2.69 |
| COP | Nominal Heating | 3.55 | |
| Max. Heating | 3.20 | ||
| SEER | Cooling | 6.27 | |
| SCOP | Heating | 4.41 | |
| ηc | Cooling | % | 248.0 |
| ηh | Heating | 173.0 | |
| Air flow rate | High | m3/h | 13,000 |
| Sound pressure level*2/ Power level |
Cooling | % | 61 / 82 |
| Heating | 63 / 83 | ||
| Max. External static pressure | Pa | 80 | |
| Compressor motor output | kW | 11.0 | |
| Heat exchanger fin | Blue fin | ||
| Net Dimensions | Height | mm | 1,690 |
| Width | 1,240 | ||
| Depth | 765 | ||
| Weight | kg | 286 | |
| Refrigerant | Type (Global Warming Potential) | R410A (2,088) | |
| Charge | kg (CO2eq-T) | 11.8 (24.6) | |
| Connection pipe diameter | Liquid | mm | 12.70 |
| Discharge Gas | 22.22 | ||
| Suction Gas | 28.58 | ||
| Operating Range | Cooling | °CDB | -10 to 46 |
| Heating | -20 to 21 | ||
| Cooling/Heating | -10 to 21 | ||
Note: Specifications are subject to the following conditions:
Cooling: Indoor temperature of 27°CDB/19°CWB, and outdoor temperature of 35°CDB/24°CWB.
Heating: Indoor temperature of 20°CDB/(15°CWB), and outdoor temperature of 7°CDB/6°CWB.
Pipe length: 7.5 m; Height difference between outdoor unit and indoor unit: 0 m.
When cooling operation is be conducted at an outdoor air temperature below -5°C, the outdoor unit must be installed in a position that is higher than or equal to that of the indoor units.
*These specifications are determined by ducted combination.
*Multiple outdoor units are not certified by Eurovent.
- Minimum connectable indoor unit number is 2.
However, the ARXC72 and ARXC90 can be used with a signal connection. - The noise level is the value measured in an anechoic room.
When measured in an actual installation, the measured value is typically larger than the indicated value due to ambient noise and reflections.
* These specifications are determined by ducted combination.
| Manufacturer | Fujitsu Airstage |
| Series | VR-IV |
| Outdoor Unit | AJY144GALDH |
| Power supply (V/ø/Hz) | 400 / 3 / 50 |
| Cooling Capacity (kW) | 45.0 |
| Heating Capacity (kW) | 42.0 |
| EER (Energy Efficiency in Cooling) | 2.69 |
| COP (Energy Efficiency in Heating) | 3.55 |
| SEER (Seasonal Cooling Efficiency) | 6.27 |
| SCOP (Seasonal Heating Efficiency) | 4.41 |
| Sound Pressure Outdoor Unit - Cooling/Heating dB(A) | 61 / 63 |
| Sound Power Outdoor Unit - Cooling/Heating dB(A) | 82 / 83 |
| Dimensions - Outdoor Unit WxHxD (mm) | 1,240 x 1,690 x 765 |
| Weight - Outdoor Unit (kg) | 286 |
| Maximum Pipe Lenght (m) | 700 |
| Maximum Height Difference (m) | 50 / 40 |
| Operation Range - Cooling (°C) | -10 ~ 46 |
| Operation Range - Heating (°C) | -20 ~ 21 |
| Refrigerant (type) | R410A |