Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU
Three-phase DVM System Samsung AM160AXVGGR/EU

Three-phase DVM System Samsung AM160AXVGGR/EU

  • Cooling
    45.00 kW
  • Heating
    45.00 kW
  • SEER
    6.90
  • SCOP
    4.30
  • Noise
    81 dB
 
Technical Specifications for Three-phase DVM System Samsung AM160AXVGGR/EU
Model AM160AXVGGR/EU
Power Supply Φ/#/V/Hz 3 / 4 / 380-415 / 50
HP 16
Capacity Cooling kW 45.00
Capacity Heating kW 45.00
Maximum number of connectable indoor units ea 29
Total capacity of the connected indoor units (Min./Max.) kW 22.50 / 58.50
Current Input Cooling A 26.96
Current Input Heating A 19.35
Current (Minimum SSC value) MVA 5.2
Current (MCA) A 32.0
Current (MFA) A 40
SEER1 W/W 6.90
SCOP1 W/W 4.30
ηs. cooling1 % 273
ηs. heating1 % 169
Compressor Output kW 8.93
Compressor Oil (Type) PVE
Compressor Oil (Initial Charge) cc 1,400
Fan (Type)

Propeller / BLDC

Air Flow m3/min 292
External Static Pressure Pa 110
Liquid Pipe ø, mm 12.70
Gas Pipe ø, mm 28.58
High Pressure Gas Pipe (HR Only) ø, mm 22.22
Piping length (ODU-IDU) (Max.) m 200
Piping length (1st Branch-IDU) (Max.) m 90
Total piping length (System) (Max.) m 1,000
Level difference (IDU-IDU) (Max.) m -
Refrigerant R410A
Factory Charging kg / tCO2e 10.5 / 21.92
Sound Pressure2 (Cooling / Heating) dB(A) 58 / 61
Sound Power dB(A) 81
Weight kg 268
Dimensions (W x H x D) mm 1295 x 1695 x 765
Operating Temperature (Cooling) °C -5 ~ 50
Operating Temperature (Heating) °C -25 ~ 24

Notes:

1Performances are based on the following test conditions:

  • Cooling: Indoor temperature: 27°C DB, 19°C WB
    Outdoor temperature: 35°C DB, 24°C WB
  • Heating: Indoor temperature: 20°C DB, 15°C WB
    Outdoor temperature: 7°C DB, 6°C WB
  • Equivalent refrigerant piping: 7.5 m, Level differences:0 m

2Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ according to operating conditions. Sound power level is an absolute value that a sound source generates.

3ODU: Outdoor Unit,
IDU: Indoor Unit

Manufacturer Samsung
Type Central air conditioning
Technology Inverter
Series DVM S2 High EER Heat Recovery
Outdoor Unit AM160AXVGGR/EU
Power supply (V/ø/Hz) 380-415 / 3 / 50
Cooling Capacity (kW) 45.00
Heating Capacity (kW) 45.00
SEER (Seasonal Cooling Efficiency) 6.90
SCOP (Seasonal Heating Efficiency) 4.30
Sound Pressure Outdoor Unit - Cooling/Heating dB(A) 58 / 61
Sound Power Outdoor Unit - Cooling/Heating dB(A) 81
Dimensions - Outdoor Unit WxHxD (mm) 1295 x 1695 x 765
Weight - Outdoor Unit (kg) 268
Piping Connections - Liquid/Gas (mm) 12.70 / 28.58
Maximum Pipe Lenght (m) 200
Maximum Height Difference Between Indoor Units (m) -
Operation Range - Cooling (°C) -5 ~ 50
Operation Range - Heating (°C) -25 ~ 24
Refrigerant R410A
No reviews
Product added to compare.

This website uses cookies. Learn more.