Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU
Three-phase DVM System Samsung AM140AXVDGH/EU

Three-phase DVM System Samsung AM140AXVDGH/EU

  • Cooling
    40.00 kW
  • Heating
    40.00 kW
  • SEER
    6.20
  • SCOP
    4.10
  • Noise
    63 dB
 
Technical Specifications for Three-phase DVM System Samsung AM140AXVDGH/EU
Model AM140AXVDGH/EU
Power Supply Φ/#/V/Hz 3 / 4 / 380-415 / 50
HP 14
Capacity Cooling kW 40.00
Capacity Heating kW 40.00
Maximum number of connectable indoor units ea 26
Total capacity of the connected indoor units (Min./Max.) kW 20.00 / 52.00
Current Input Cooling A 28.60
Current Input Heating A 20.91
Current (MCA) A 29.0
Current (MFA) A 32
SEER1 W/W 6.20
SCOP1 W/W 4.10
ηs. cooling1 % 245
ηs. heating1 % 161
Compressor (Type) Inverter Scroll
Compressor Output kW 6.67
Compressor Oil (Type) PVE
Compressor Oil (Initial Charge) cc 1,100
Fan (Type) Propeller / BLDC
Air Flow m3/min 210
External Static Pressure Pa 80
Liquid Pipe ø, mm 12.70
Gas Pipe ø, mm 28.58
Piping length (ODU-IDU)3 (Max.) m 200
Piping length (1st Branch-IDU)3 (Max.) m 90
Total piping length (System)3 (Max.) m 1,000
Level difference (IDU-IDU)3 (Max.) m 50
Refrigerant R410A
Factory Charging kg / tCO2e 7.0 / 14.62
Sound Pressure2 (Cooling / Heating) dB(A) 63 / 65
Sound Power dB(A) 85
Weight kg 207
Dimensions (W x H x D) mm 930 x 1695 x 765
Operating Temperature (Cooling) °C -5 ~ 50
Operating Temperature (Heating) °C -25 ~ 24

Notes:

1Performances are based on the following test conditions:

  • Cooling: Indoor temperature: 27°C DB, 19°C WB
    Outdoor temperature: 35°C DB, 24°C WB
  • Heating: Indoor temperature: 20°C DB, 15°C WB
    Outdoor temperature: 7°C DB, 6°C WB
  • Equivalent refrigerant piping: 7.5 m, Level differences:0 m

2Sound pressure level is obtained in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. Sound pressure level may differ according to operating conditions. Sound power level is an absolute value that a sound source generates.

3ODU: Outdoor Unit,
IDU: Indoor Unit

Manufacturer Samsung
Type Central air conditioning
Technology Inverter
Series DVM S2 Essential
Outdoor Unit AM140AXVDGH/EU
Power supply (V/ø/Hz) 380-415 / 3 / 50
Cooling Capacity (kW) 40.00
Heating Capacity (kW) 40.00
SEER (Seasonal Cooling Efficiency) 6.20
SCOP (Seasonal Heating Efficiency) 4.10
Sound Pressure Outdoor Unit - Cooling/Heating dB(A) 63 / 65
Sound Power Outdoor Unit - Cooling/Heating dB(A) 85
Air Flow Outdoor Unit (m3/min) 210
Dimensions - Outdoor Unit WxHxD (mm) 930 x 1695 x 765
Weight - Outdoor Unit (kg) 207
Piping Connections - Liquid/Gas (mm) 12.70 / 28.58
Maximum Pipe Lenght (m) 200
Maximum Height Difference Between Indoor Units (m) 50
Operation Range - Cooling (°C) -5 ~ 50
Operation Range - Heating (°C) -25 ~ 24
Refrigerant R410A
No reviews
Product added to compare.

This website uses cookies. Learn more.