Your cart
There are no more items in your cart
| Outdoor Unit | AJ050TXJ2KG/EU | ||
|---|---|---|---|
| Maximum number of connectable indoor units | 2 | ||
| Capacity | |||
| Capacity | Cooling (Nominal) | kW | 5.0 |
| Heating @ +7 °C | kW | 5.6 | |
| Heating @ -5 °C | kW | 4.22 | |
| Heating @ -10 °C | kW | 3.60 | |
| Heating @ -15 °C | kW | 2.98 | |
| Performance | |||
| Energy Efficiency Cooling | SEER 1 | W/W | 8.54 |
| Power Consumption | kWh/a | 205 | |
| Pdesignc | kW | 5.0 | |
| EER | W/W | 4.10 | |
| Energy Efficiency Heating | SCOP 1 | W/W | 4.64 |
| Power Consumption | kWh/a | 1,270 | |
| Pdesignh (average) | kW | 4.2 | |
| COP 1 | W/W | 4.38 | |
| Airflow Rate | m3/min | 33.1 | |
| Sound Power | dB(A) | 61 | |
| Sound Pressure | Cooling | dB(A) | 46 |
| Heating | dB(A) | 47 | |
| Fan | Type | Propeller Fan | |
| Discharge direction | Front (horizontal) | ||
| Power | W | 40 | |
| Number of Fans | - | 1 | |
| Operating Temperature Range | Cooling | °C | -5.0~46.0 |
| Heating | °C | -15~24 | |
| Electrical Data | |||
| Power Source | Φ, V, Hz | 1Φ, 220~240 V, 50 Hz | |
| Compressor Type | Twin BLDC Rotary | ||
| Power Consumption | Cooling | kW | 1.22 |
| Heating | kW | 1.28 | |
| Operating Current | Cooling | A | 5.6 |
| Heating | A | 5.9 | |
| Dimensions | |||
| Net Dimensions (W x H x D) | mm | 790 x 548 x 285 | |
| Net Weight | kg | 33.0 | |
| Refrigerant | |||
| Refrigerant | Type | R32 (contains fluorinated greenhouse gases. GWP = 675) | |
| Factory Charging | kg | 1.18 | |
| Chargeless Piping Length | m | 30.0 | |
| Charging Ton equivalent CO2 | tCO2e | 0.80 | |
| Additional Refrigerant Charging | g/m | - | |
| Piping Connections | Liquid Pipe | ø, inch | 1/4 x 2 |
| Gas Pipe | ø, inch | 3/8 x 2 | |
| Piping Length | Total Piping Length | m | 30 |
| Min/Max | m | 3/25 | |
| Piping Height | Max Height (ID-ID) | m | 7.5 |
| Max Height (OD-ID) | m | 15 | |
| Outdoor Unit | AJ050TXJ2KG/EU |
| Power supply (V/ø/Hz) | 230 / 1 / 50 |
| Cooling Capacity (kW) | 5.0 |
| Heating Capacity (kW) | 4.22 |
| Pdesign Heating (-7°C) (kW) | 4.2 |
| SEER (Seasonal Cooling Efficiency) | 8.54 |
| SCOP (Seasonal Heating Efficiency) | 4.64 |
| Energy Efficiency Class (Cooling) | A+++ |
| Energy Efficiency Class (Heating) | A++ |
| Current for Cooling / Heating (A) | 5.6 / 5.9 |
| Sound Pressure Outdoor Unit - Cooling/Heating dB(A) | 46 / 47 |
| Sound Power Outdoor Unit - Cooling/Heating dB(A) | 61 / 61 |
| Dimensions - Outdoor Unit WxHxD (mm) | 790 x 548 x 285 |
| Weight - Outdoor Unit (kg) | 33.0 |
| Piping Connections - Liquid/Gas (mm) | 1/4 x 3 / 3/8 x 2 |
| Maximum Height Difference Between Outdoor and Each Indoor Unit (m) | 15 |
| Maximum Height Difference Between Indoor Units (m) | 7.5 |
| Operation Range - Cooling (°C) | -5.0 ~ 46.0 |
| Operation Range - Heating (°C) | -15 ~ 24 |
| Refrigerant (type) | R32 |
| Warranty | 3 years |